The ACU20FD digital mass flow meter comprises a mass flow sensor, a laminar‑flow element, a flow‑control regulating valve, and an amplification‑and‑control circuit. It employs digital signal input and output and features short warm‑up time, minimal zero drift, and high reliability.

Overview
Applications
Specifications
Dimensions
Software
◆ Thermal‑anemometer principle, offering higher accuracy, faster response, and a network port.
◆ Tubular shunt, less prone to blockage
◆ Suitable for various low-pressure and high-pressure pipelines
◆ Short warm-up time, minimal zero drift, and high reliability
◆ Analog inputs/outputs can use secondary instruments or flow computers to control and display flow rates.
ACU20FD High-precision mass flow meter/flow controller The mass flow rate of a gas is measured using the principle of differential‑temperature calorimetry based on capillary heat transfer, which is unaffected by temperature and pressure. The flow signal acquired by the sensor is amplified and compared with a setpoint voltage; the resulting error signal drives a control valve, thereby implementing closed‑loop regulation to maintain the flow through the channel at the desired setpoint.
| Glass industry | Solar energy | Atmospheric Monitoring | Industrial manufacturing | Petroleum and Petrochemicals |
| Coal Metallurgy | Gas production and gas distribution | Environmental protection | Various instrumental analyses | |
| Series | ACU20FD | |||
| Model number | LC | LM | MC | MM |
| Measurement range | 0–(2, 5, 10…1000) SCCM, 0–(1, 5, 10…30) SLM | 0-(30,40,50...300)SLM | ||
| Accuracy | ±0.5%F.S | |||
| Linear | ±0.25%F.S | |||
| Repeatability | ±0.2%F.S | |||
| Response time | <0.2s | <0.1s | <0.2s | <0.1s |
| Working differential pressure | 0.1–0.5 MPa (to be specified at the time of order) | |||
| Range ratio | 50:1 | 100:1 | 50:1 | 100:1 |
| Analog quantity | 0–5 V, 4–20 mA | |||
| Digital quantity | RS232/485, MODBUS protocol | |||
| Power supply | 24VDC | |||
| Communication protocol | Modbus, DeviceNet, Profinet, EtherCAT, Profibus, and others | |||
| Operating temperature | 0~50℃ | |||
| Maximum withstand voltage | 3 MPa / 10 MPa (to be specified at the time of order) | |||
| Electrical connection | DB9 port | |||
| Display screen | Touchscreen display | |||
| Leak rate | 1×10 ⁻9 Pa m 3/S | |||
| Protection rating | IP40 | |||
| Valve | Valve remains open | / | Valve remains open | / |
| Base material | Stainless steel | |||
| Sealing material | Fluororubber, nitrile rubber, EPDM, perfluoroether | |||
| Body thread | G3/8 internal thread G1/2 internal thread | |||
| Joint | Ferrules, ferrule fittings, quick-connect couplings, VCR fittings, flanges, and more | |||
Mass Flow Measurement and Control System V5.0