The ACU20FD digital mass flow controller comprises a mass flow sensor, a laminar flow element, a flow‑control regulating valve, and an amplification control circuit. It features digital signal input and output, short warm‑up time, low zero drift, and high reliability.
Range: (600-10000) SLM

Overview
Applications
Specifications
Dimensions
Software
◆ Thermal principle, fast response, high accuracy
◆ Tubular shunt, less prone to blockage
◆ Suitable for various low-pressure and high-pressure pipelines
◆ Short warm-up time, minimal zero drift, and high reliability
◆ Analog inputs/outputs can use secondary instruments or flow computers to control and display flow rates.
The ACU20FD is a high‑precision flow meter/controller with a measurement error of only ±0.5% of full scale. Its exceptional accuracy stems from a unique sensor probe: this hermetically sealed probe incorporates two sensing elements— a velocity sensor and a temperature sensor—enabling automatic compensation for the effects of temperature and pressure variations. The instrument’s electronic circuitry heats the velocity sensor to a constant temperature above that of the gas or liquid, then measures the cooling effect caused by the gas flow. Flow rate is calculated based on the principle that the electrical power required to maintain a constant temperature difference is directly proportional to the gas mass flow rate. Both sensors are standard‑grade platinum resistance temperature detectors (RTDs), sealed within a stainless‑steel housing.
| Glass industry | Solar energy | Atmospheric monitoring | Industrial manufacturing | Petroleum and Petrochemicals |
| Coal Metallurgy | Gas production and gas distribution | Environmental protection | Various instrumental analyses | |
| Series | ACU20FDR | |||||||
| Model number | LC | LM | MC | MM | BC | BM | HC | HM |
| Measurement range | 0 (50, 200, 300...600) SLM | 0–(600, 700…1200) SLM | 0–(1200, 1500…4000) SLM | 0-(4000,4200...6000)SLM | ||||
| Accuracy | ±0.5%F.S | |||||||
| Linear | ±0.25%F.S | |||||||
| Repeatability | ±0.2%F.S | |||||||
| Working differential pressure | 0.01–0.5 MPa (to be specified at the time of order) | |||||||
| Response time | <0.2s | <0.1s | <0.2s | <0.1s | <0.2s | <0.1s | <0.2s | <0.1s |
| Range ratio | 50:1 | 100:1 | 50:1 | 100:1 | 50:1 | 100:1 | 50:1 | 100:1 |
| Preheating time | < 5 seconds | |||||||
| Analog quantity | 0–5 V, 4–20 mA | |||||||
| Digital quantity | RS232/485, MODBUS protocol | |||||||
| Power supply | 24VDC | |||||||
| Communication protocol | Modbus, DeviceNet, Profinet, EtherCAT, Profibus, and others | |||||||
| Operating temperature | 0~50℃ | |||||||
| Maximum withstand voltage | 1 MPa (specified at the time of order) | |||||||
| Electrical connection | DB9 port | |||||||
| Monochrome LCD display | Displays flow rate and setpoint simultaneously. | |||||||
| Maximum withstand voltage | 1MPa | |||||||
| Leak rate | 1×10 -9 Pa m³/S | |||||||
| Protection rating | IP40 | |||||||
| Base material | Stainless steel | |||||||
| Sealing material | Fluororubber, nitrile rubber, EPDM, perfluoroether | |||||||
| Body thread | G3/4 internal thread | 1 inch | ||||||
| Joint | Ferrules, ferrule fittings, quick-connect couplings, VCR fittings, flanges, and more | |||||||
Mass Flow Measurement and Control System V5.0