In many production processes, when two or more components need to be mixed together, a traditional foaming system is generally used to evaporate the liquid in the carrier gas. This method is insufficient for processing liquids with low vapor pressure and cannot achieve real-time mixing and evaporation according to vapor pressure. The ACCU gas-liquid mixing evaporation system overcomes these problems and achieves fast, accurate, and efficient mixing and evaporation control.
Maximum gasification capacity: 120g/h

Overview
Specifications
Applications
Software
The ACCU gas-liquid mixed evaporation system consists of five parts: a liquid flow controller (for controlling the liquid source flow rate), one or more gas mass flow controllers (for controlling the carrier gas flow rate), a temperature-adjustable mixed evaporator (for liquid vaporization); an optional flow and temperature display controller (for setting flow rate and temperature), and an optional post-vaporization dilution gas flow controller (for diluting the output vapor).
◆A typical CEM system is shown in Figure 1, where a three-way display controller connects and independently controls the liquid flow, gas flow, and evaporation temperature. A PLC and DCS system can replace the display controller, achieving centralized control through protocols such as MODBUS or DEVICENET.
◆According to site needs, one or more carrier gas flow controllers can be added to achieve multi-component carrier gas injection.
◆A three-way valve can be added to the steam outlet, connecting a gas mass flow controller to dilute the output steam.

Figure 1, Typical CEM System
2.1 Temperature-Controllable Mixed Evaporator
| Product Model | ACU20CEM | |||
| Maximum Vaporization Capacity | 1200g/h | |||
| Pressure Rating | 10MPA | |||
| Maximum Temperature | 300℃ | |||
| Connector | VCR, Compression Fitting | |||
2.2 Flow/Temperature Display Controller
| Product Model | ACU20CEM | |||
| Power Supply | 220V | |||
| Analog Signal | 0-5V or 4-20mA | |||
| Digital Signal | MODBUS (RS232/485), PROFIBUS, DEVICENET protocols | |||
| Display Type | LCD with Touchscreen | |||


Mass Flow Monitoring and Control System V5.0